Model #
FRP12ETT2R
PTAC unit with Electric Heat 12,000 BTU 208/230V without Seacoast Protection
Effortless™ Maintenance
- With Frigidaire®’s reputation for durability, easy maintenance, availability of reliable parts, and service you can count on, you can be sure that you’re getting the highest-quality performance.
- Sound reduction package.
- Provides nine diagnostic points for self-check and correction of fault conditions.
- Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Auto Restart and Ready-Select® LCD controls reduce maintenance calls.
- In the event of a power outage, self-enabling Effortless™ restart feature automatically resumes operating at previous settings when power is restored.
- Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times, while controling energy usage.
- Energy Saver Mode can help reduce your utility bills, while still keeping guests cool, by maximizing energy efficiency. In this mode, the unit doesn't run at all times, it turns on and off at different intervals to ensure that the room temperature stays at the set temperature.
- Offers your guests more cooling flexibility with three adjustable fan settings as well as cool, heat and fan-only options.
- Frigidaire® PTACs are designed to make guest's time away from home even easier. By adding an optional remote thermostat, you can allow guests to effortlessly control their temperature and air movement from anywhere in the room.
- The upfront location of the filter makes regular cleaning quick and effortless, prolonging the life of the unit.
- Unit operates at a low voltage to protect unoccupied rooms from freezing temperatures.
- Simply select options with the touch of a button.
- Delays restart after a power outage to protect the electrical circuit from power surges.
AC | |
Auto Restart | Yes |
Filter Access - Frig | Slide-Out |
Smart Self-Check | Yes |
Slide-Out Chassis | Yes |
Cabinet Louvers | No |
Air Intake | Fresh or Recycled Air |
Airflow | Continuous or Cycled |
Quiet Start-Up | Yes |
Fan Auto | Yes |
24-Hour On/Off Timer | Yes |
Front Desk Control Ready | Yes |
Low Voltage Start-up | Yes |
Random Restart Protection | Yes |
Motor RPM (High/Med/Low) | 1100/1000/920 |
Fan Speeds - Cool/Fan/Heat | 2003-03-03 |
AC Specifications | |
Filter Type | PA/Nylon Mesh |
Fin Coating | Normal |
Room Freeze Protection | Yes |
Air Direction Control | Auxiliary 2-Way |
Air Volume (CFM) (Max./Med./Min.) | 315/295/275 |
Energy Saver | Yes |
Charge (ozs) | 26.8 |
Noise Level dB (High/Med/Low) | 53/52/51 |
Certifications & Approvals | |
Safety Certification | UL/CUL/CSA |
Controls | |
Controls | Electronic |
Control Location | Top Right |
Dimensions: Cut-Out | |
Height (Min) | 16-5/16" |
Width (Min) | 42-3/16" |
Dimensions: Exterior | |
Depth | 13-13/16" |
Cabinet Height | 16" |
Cabinet Depth | 13-13/16" |
Width | 42" |
Height | 16" |
Electrical Specifications | |
Power Cord Length | 5-1/2' |
Voltage Rating | 230V / 208V 60Hz |
Cable Included | Yes |
Amps (Electrical Heat) | 13.2 / 12.2 |
Plug Type | LCDI 6-20P |
Horsepower (Cool) | 1.5 |
Amps (Cool) | 5.1 / 5.3 |
Watts (ElectricalHeat) | 3000 / 2452 |
Circuit Breaker | 20A |
Watts (Cool) | 1120 / 1120 |
Exterior Dimensions | |
Case Width | 42" |
General Specifications | |
Refrigerant | R410a |
Warranty | 2 Year Full/5 Year Sealed System |
Stack Height | 6 |
Max Wall Thickness | 13-13/16" |
Stuff Quantity | 180 |
Shipping Weight (lbs) | 141 |
Performance | |
Performance Certification | AHRI & CEC |
BTU (Electrical Heat) | 10200 / 8300 |
BTU (Cool) | 12000 / 11800 |
Dehumidification (Pints/Hour) | 2.7 |
Cool Area (Sq. Ft.) | 640 |
Energy Efficiency Ratio | 10.7 / 10.5 |
Extended warranties can save you hundreds, sometimes even thousands of dollars in unexpected repairs. You can contact us, or visit our store for additional details.
Let our team co-ordinate professional delivery and installation on your new purchase. Some restrictions may apply.
Proposition 65 Warning for California Residents
Cancer and Reproductive Harm - P65Warnings.ca.gov
Features
Effortless™ Maintenance
- With Frigidaire®’s reputation for durability, easy maintenance, availability of reliable parts, and service you can count on, you can be sure that you’re getting the highest-quality performance.
- Sound reduction package.
- Provides nine diagnostic points for self-check and correction of fault conditions.
- Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Auto Restart and Ready-Select® LCD controls reduce maintenance calls.
- In the event of a power outage, self-enabling Effortless™ restart feature automatically resumes operating at previous settings when power is restored.
- Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times, while controling energy usage.
- Energy Saver Mode can help reduce your utility bills, while still keeping guests cool, by maximizing energy efficiency. In this mode, the unit doesn't run at all times, it turns on and off at different intervals to ensure that the room temperature stays at the set temperature.
- Offers your guests more cooling flexibility with three adjustable fan settings as well as cool, heat and fan-only options.
- Frigidaire® PTACs are designed to make guest's time away from home even easier. By adding an optional remote thermostat, you can allow guests to effortlessly control their temperature and air movement from anywhere in the room.
- The upfront location of the filter makes regular cleaning quick and effortless, prolonging the life of the unit.
- Unit operates at a low voltage to protect unoccupied rooms from freezing temperatures.
- Simply select options with the touch of a button.